FLUKE a3000 FC Wireless AC Clamp Kit FLUFLKA3000FCKIT

SKU
..143259
MPN FLUFLKA3000FCKIT
In Stock
$1210
Free Delivery
 

GET TO WORK NOW, PAY LATER Click to see your options

Paypal
4x payments of $302.50
Zip
Available for orders up to $5,000
Afterpay
Love tools? Start earning points to redeem rewards on your next purchase Log in or Sign Up to redeem today!
Product Review Winner
Top 100 Relailer
30 Day Online Returns' with 'Australia's largest professional tool retailer

Connect the a3000 FC Wireless AC Current Clamp Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Clamp Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:

  • True-RMS AC clamp meter
  • Measure up to 400 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function

Specifications:

Fluke 3000 FC Series Wireless Multimeter

  • AC Voltage Range / Resolution:
    • 600.0 mV / 0.1 mV
    • 6.000 V / 0.001 V
    • 60.00 V / 0.01 V
    • 600.0 V / 0.1 V
    • 1000 V / 1 V
  • AC Voltage Accuracy:
    • 45 Hz to 500 Hz 1.0% + 3
    • 500 Hz to 1 kHz 2.0% + 3
  • mV Range / Resolution: 600.0 mV / 0.1 mV
  • mV Accuracy: 0.09% + 2
  • V Range / Resolution:
    • 6.000 V / 0.001 V
    • 60.00 V / 0.01 V
    • 600.0 V / 0.1 V
    • 1000 V / 1 V
  • V Accuracy:
    • 0.09% + 2
    • 0.15% + 2
  • Range / Resolution: 600 Ω / 1 Ω
  • Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
  • Ω Range / Resolution:
    • 600.0 Ω / 0.1 Ω
    • 6.000 kΩ / 0.001 kΩ
    • 60.00 kΩ / 0.01 kΩ
    • 60.00 kΩ / 0.1 kΩ
    • 600.0 kΩ / 0.001 MΩ
    • 50.00 MΩ / 0.01 MΩ
  • Ω Accuracy:
    • 0.5% + 2
    • 0.5% + 1
    • 1.5% + 3
  • Diode test Range / Resolution: 2.000 V / 0.001 V
  • Diode test Accuracy: 1% + 2
  • µF Range / Resolution:
    • 1000 nF / 1 nF
    • 10.00 μF / 0.01 μF
    • 100.0 μF / 0.1 μF
    • 9999 μF1 / 1 μF
  • µF Accuracy:
    • 1.2% + 2
    • 10% typical
  • mA AC (45 Hz to 1 kHz) Range / Resolution:
    • 60.00 mA / 0.01 mA
    • 400.0 mA 3/ 0.1 mA
  • mA AC (45 Hz to 1 kHz) Accuracy: 1.5% + 3
  • mA DC Range / Resolution:
    • 60.00 mA / 0.01 mA
    • 400.0 mA 3/ 0.1 mA
  • mA DC Accuracy: 0.5% + 3
  • Frequency Range / Resolution:
    • 99.99 Hz / 0.01 Hz
    • 999.9 Hz / 0.1 Hz
    • 9.999 kHz / 0.001 kHz
    • 99.99 kHz / 0.01 kHz
  • Frequency Accuracy: 0.1% + 1
  • mA Function Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
  • mA Function Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
  • MIN/MAX Recording Accuracy DC functions: The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
  • MIN/MAX Recording Accuracy AC functions: The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
  • Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS
  • Ω fuse protection from A inputs:0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
  • Display (LCD):Update rate: 4/sec
    • Volts, amps, ohms: 6000 counts
    • Frequency: 10,000 counts
    • Capacitance: 1,000 counts
  • Battery type: 3 x AA Alkaline batteries, NEDA 15A IEC LR6
  • Battery life: 250 hours minimum
  • RF communications: 2.4 GHZ ISM Band
  • RF communication range:
    • Open air, unobstructed: Up to 20m
    • Obstructed, sheetrock wall: Up to 6.5m
  • Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
  • Operating Temperature: -10°C to 50°C
  • Storage Temperature: -40°C to 60°C
  • Temperature coefficient: 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
  • Relative humidity:
    • 0% to 90% (0°C to 35°C)
    • 0% to 75% (35°C to 40°C)
    • 0% to 45% (40°C to 50°C)
  • Operating Altitude: 2,000 m
  • Storage Altitude: 12,000 m
  • Electromagnetic compatibility - EMI, RFI, EMC, RF
    • EN 61326–1:2006, EN 61326–2–2:2006
    • ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    • V1.8.1:2008
    • FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    • FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
  • Safety compliance:
    • ANSI / ISA 61010–1 / (82.02.01): 3rd edition
    • CAN / CSA-C22.2 No 61010-1-12: 3rd edition
    • UL 61010–1: 3rd edition
    • IEC / EN 61010–1:2010
  • Certifications: CSA, FCC, CE
  • Ingress Protection (IP) rating: IP54
  • Pollution Degree: 2
  • Dimensions (L x W x H): 207mm x 93mm x 47.5mm
  • Weight: 0.34kg

Fluke a3000 FC Wireless AC Current Clamp Module

  • Range: 0.5 A to 400.0 A
  • Resolution: 0.1 A
  • 400.0 A Accuracy:
  • 2% ±5 digits (10 Hz to 100 Hz)
  • 2.5% ±5 digits (100 Hz to 500 Hz)
  • Inrush Max displayed reading: 999.9A
  • Crest factor (50 Hz / 60 Hz):
    • 3 at 500 A (add 2% for C.F. > 2)
    • 2.5 at 600 A (add 2% for C.F. > 2)
    • 1.42 at 1000 A (add 2% for C.F. > 2)
  • LCD w/ backlight: 3½ digits
  • Log rate/interval: 1 sec minimum/adjustable by PC
  • Battery type: 2 x AA, NEDA 15 A, IEC LR6
  • Battery life: 400 hours
  • Memory: Record up to 65,000 readings
  • RF communications: 2.4 GHZ ISM Band
  • RF communication range:
    • Open air, unobstructed: Up to 20 m
    • Obstructed, sheetrock wall: Up to 6.5 m
    • Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
  • Operating temperature: -10°C to +50°C
  • Storage temperature: -40°C to +60°C
  • Temperature coefficient: Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
  • Operating humidity:
    • 90% at 35°C
    • 75% at 40°C
    • 45% at 50°C
  • Operating Altitude: 2,000 m
  • Storage Altitude: 12,000 m
  • EMC: EN 61326-1:2006
  • Safety compliance: IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
  • Safety rating: CAT III 600 V
  • Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
  • Ingress Protection (IP) rating: IP30
  • Pollution Degree: 2
  • Jaw opening: 34 mm (1.33 in)
  • Dimensions (L x W x H): 35.5mm x 74.9mm x 203mm
  • Weight: 0.22kg
Specification
Part No FLUFLKA3000FCKIT
Barcode 95969724203
Brand Fluke

Reviews