FLUKE CNX 3000 Industrial System FLUFLK3000FCIND
Pickup In Store
If you don't want to pay for delivery or need to ASAP, you can pick it up in store. Just bear in mind not all stores will have everything in stock. You'll be able to see if they do during the checkout process.
Free Delivery
Most products are included in free delivery, however some are excluded as follows:
- Orders and/or items under $99.
- Orders and/or items that are deemed bulky, large or heavy.
- Clearance items.
- Orders that include or items that are classed as dangerous goods.
- Remote areas are excluded from free delivery and you will either be charged delivery at checkout or may be contacted prior to delivery to confirm delivery charges if necessary.
- Interstate deliveries.
Total Tools reserve the right to change or withdraw free delivery at any time.
Estimated Delivery Timeframes
If you opted to collect in store you will receive an email to inform you when your goods are ready for collection.
If you opted for delivery, you will receive an email when the goods have been despatched to the couriers with details so you can track our order.
We aim to despatch all orders within 1-2 business days. In the unusual event of a delay to the despatch of your order you will be contacted at the earliest opportunity. Once the order has been despatched the estimated delivery time is as follows:
- Metro (Excludes Hobart Metro) 1-2 business days
- Hobart Metro 3-4 business days
- Regional Areas 3-4 business days
- Remote Areas 6-9 business days
Please note that these delivery timeframes are estimates and are not guaranteed.
Returns
Changed your mind? No worries. You just need to get the product back to the store it was shipped from (this is on your receipt) within 30 days, unused and in its original packaging and we'll give you a refund (excluding delivery costs). You can read our full returns & exchanges policy here (special order items are excluded from this returns policy).
Total Tools - Low Price Guarantee Policy (Terms & Conditions)
At Total Tools we offer Low Prices, every day, guaranteed. We will not be beaten!
We check our prices daily against our competitors to ensure you can shop online or instore with the confidence you are buying at the very best price, every day.
Should you find a lower advertised price for the identically stocked product elsewhere, we will happily match the price. [Subject to Terms & Conditions – see below for details]
At times prices have moved in the market, and our in store and online price for printed catalogue items may be lower. Check online or instore for the latest price.
How to Price Match
Simply fill in price match form available on every product page or visit a Total Tools Store. We will verify the price, and then immediately match any current advertised price (Terms & Conditions apply).
Terms & Conditions
For eligibility, the following terms and conditions need to be met;
- Product must be identical (same brand, colour, model #)
- Product must be currently advertised in print or electronic media (Including newspaper, catalogue, radio, television advertising or online)
- Product must be in stock at the competitor
- The competitors price of the product must be inclusive of delivery fees, taxes and charges
- The competitors price is lower than our price on the day the price guarantee is requested (day of purchase)
- The competitors price excludes finance, installation, bundling, rebates, cash back, coupon offers, loyalty rewards or free bonus goods.
- The competitor is located in Australia
The following exclusions apply;
- Trade/commercial quotes and/or large volume/bulk purchases
- Products for sale via auction, stock liquidations, fire sale, sale or clearance (including eBay, Amazon)
- Blemished, seconds, refurbished, damaged or ex demonstration stock
- Advertising errors where competitor has published a rectification notice
- Special event, club or membership offers, third party promotions or prices not available to the general public
- Special order products
Total Tools reserve the right to terminate or amend the price guarantee policy at any time without notice.
For Further Information
Further information may be obtained in-store at any of our stores nationwide or online at www.totaltools.com.au/price-match-guarantee. Alternatively, contact onlinesupport@totaltools.com.au.
The Fluke CNX™ 3000 Industrial System lets you work on electrical panels faster, safer, easier.
Denergize the cabinet, connect the remote modules, close the cabinet and reenergize. The CNX™ 3000 Industrial System displays the readings wirelessly on the CNX multimeter.
Connect the three CNX i3000 iFlex AC Wireless Current Modules to your test points, and view the results from all three phases in 1/3 the time and cost of current test methods. Or connect the CNX v3000 AC Wireless Voltage Module and view both voltage and current measurements simultaneously. You'll get better answers, faster, and spend less time in full PPE.
From short distances, you can even view readings from modules through closed electrical panels. Plus the CNX remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm's way.
The CNX 3000 Industrial System provides measurement of all common electrical parameters.
The CNX 3000 Wireless Multimeter offers:
- True RMS AC and DC voltage measurements to 1000V
- True RMS AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V; CAT IV 600 V; IP54
The CNX i3000 iFlex AC Wireless Current Module offers:
- True RMS AC current measurements to 2500 A
- 3% accuracy
- Memory recording up to 65,000 readings
- iFlex current probe allows you to get into tight, awkward spaces
- Backlit LCD display
- CAT III 1000, CAT IV 600 V, CAT III 1000 V; IP42
The CNX v3000 AC Wireless Voltage Module offers:
- True RMS AC voltage measurements to 1000V
- ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
- Memory recording up to 65,000 readings
- Backlit LCD display
- CAT IV 600 V, CAT III 1000 V; IP42
The CNX wireless system can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.
Specifications:
CNX 3000 Wireless Multimeter
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications | ||||
AC Voltage | ||||
Range ¹ | Resolution | Accuracy ² ³ | ||
45 Hz to 500 Hz | 500 Hz to 1 kHz | |||
600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 | |
6.000 V | 0.001 V | |||
60.00 V | 0.01 V | |||
600.0 V | 0.1 V | |||
1000 V | 1 V | |||
Notes: ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||||
Function | Range | Resolution | Accuracy | |
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 | |
V | 6.000 V | 0.001 V | 0.09 % + 2 | |
60.00 V | 0.01 V | |||
600.0 V | 0.1 V | |||
1000 V | 1 V | 0.15 % + 2 | ||
Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
Ω | 600.0 Ω | 0.1 Ω | 0.5 % + 2 | |
6.000 kΩ | 0.001 kΩ | 0.5 % + 1 | ||
60.00 kΩ | 0.01 kΩ | |||
60.00 kΩ | 0.1 kΩ | |||
600.0 kΩ | 0.001 MΩ | |||
50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | ||
Diode test | 2.000 V | 0.001 V | 1 % + 2 | |
μF | 1000 nF | 1 nF | 1.2 % + 2 | |
10.00 μF | 0.01 μF | |||
100.0 μF | 0.1 μF | |||
9999 μF¹ | 1 μF | 10 % typical | ||
Notes: ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. |
AC and DC Current | ||||
Function | Range ¹ | Resolution | Accuracy | |
mA AC (45 Hz to 1 kHz) |
60.00 mA | 0.01 mA | 1.5 % + 3 | |
400.0 mA ³ | 0.1 mA | |||
mA DC ² | 60.00 mA | 0.01 mA | 0.5 % + 3 | |
400.0 mA | 0.1 mA | |||
Notes: ¹ All AC current ranges are specified from 5 % of range to 100 % of range. ² Input burden voltage (typical): 400 mA input 2 mV/mA. ³ 400.0 mA accuracy specified up to 600 mA overload. |
Frequency | ||||
Range | Resolution | Accuracy ¹ | ||
99.99 Hz | 0.01 Hz | 0.1 % + 1 | ||
999.9 Hz | 0.1 Hz | |||
9.999 kHz | 0.001 kHz | |||
99.99 kHz | 0.01 kHz | |||
Notes: ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. |
Input Characteristics | ||||
Function | Overload Protection |
Input Impedance (nominal) |
Common Mode Rejection Ratio (1 kΩ unbalance) | Normal Mode Rejection |
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz | |
1100 V RMS | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | ||
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz | |
Open circuit test voltage | Full scale | Typical short circuit current | ||
1100 V RMS | < 2.7 V DC | To 6 MΩ: < 0.7 V DC 50 MΩ: < 0.9 V DC |
< 350 mA | |
1100 V RMS | < 2.7 V DC | To 6 MΩ: 2.000 V DC | < 1.1 mA |
Function | Overload Protection | Overload | ||
mA | Fused, 44/100 A, 1000 V FAST Fuse |
600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
MIN/MAX Recording | ||||
Function | Accuracy | |||
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. | |||
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
General Specifications | ||||
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | |||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |||
Display (LCD) | Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
|||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | |||
Battery life | 300 hours minimum | |||
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
|||
Relative humidity | 0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) |
|||
Altitude | Operating: 2,000 m Storage: 12,000 m |
|||
Temperature coefficient | 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) | |||
Wireless frequency | 2.4 GHz ISM Band 20 meter range | |||
Size (HxWxL) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
|||
Weight | 340 g (12 oz) | |||
Safety standards | US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010 |
|||
Electromagnetic compatibility EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS |
|||
Ingress Protection (IP) rating | IP54 | |||
Notes: • Accuracy is specified as ± ([% of reading] + [number of least significant digits]). • All ranges are autoranging. • Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C. |
Fluke CNX i3000 iFlex AC Wireless Current Module
Specifications | |
Range | 2500 A AC |
Resolution | 0.1 A to 999.9, 1A from 1000 to 2500 |
Accuracy | 3 % ± 5 digits |
Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
Display | 3-1/2 digits, LCD w/backlight |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel |
Battery type | 2 AA, NEDA 15 A, IEC LR6 |
Battery life | 400 hours |
Memory | Record up to 65,000 readings |
RF communications | 2.4 GHZ ISM Band |
RF communication range | 20 Meters |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Operating humidity | 90 % at 35 °C 75 % at 40 °C 45 % at 50 °C |
EMC | EN 61326-1:2006 |
Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 610101-2-031:2002 EN/IEC 61010-2-032:2002 |
Pollution degree | 2 |
Temperature coefficient | Add 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C) |
Safety rating | CAT IV 600 V, CAT III 1000 V |
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS |
Ingress Protection (IP) rating | IP42 |
Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | .22 kg (8 oz) |
Jaw opening | 25.4 cm (10 in) coil |
Fluke CNX v3000 AC Wireless Voltage Module
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage | |||
Range ¹ | Resolution | Accuracy ² ³ | |
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
6.000 V | 0.001 V | 1.0 % + 3 | 2.0 % + 3 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | ||
Notes: ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. ² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. |
General Specifications | |||
LCD w/backlight | 3½ digits, 6000 counts, updates 4/sec | ||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | ||
Battery life | 400 hours | ||
Memory | Record up to 65,000 readings | ||
Unbound listen interval | 5 seconds | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range | 20 Meters | ||
Operating temperature | -10 °C to +50 °C | ||
Storage temperature | -40 °C to +60 °C | ||
Operating humidity | 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C | ||
EMC | EN 61326-1:2006 | ||
Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 61010-031:2002+A1:2008 |
||
Pollution degree | 2 | ||
Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C) | ||
Safety rating | CAT IV 600 V, CAT III 1000 V | ||
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS | ||
Ingress Protection (IP) rating | IP42 | ||
Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) | ||
Weight | .22 kg (8 oz) |
Part No | FLUFLK3000FCIND |
---|---|
Barcode | 95969724180 |
Brand | Fluke |
Net Weight (kg) | 4.28 |
Product Length (mm) | 445 |
Product Width (mm) | 260 |
Product Height (mm) | 180 |