FLUKE Wireless AC-DC Voltage Multimeter Kit FLUFLKV3003FCKIT

SKU
..182330
MPN FLUFLKV3003FCKIT
In Stock
  • Warranty: 1 Year
$1656
Free Delivery
 

GET TO WORK NOW, PAY LATER Click to see your options

Paypal
4x payments of $414
Zip
Available for orders up to $5,000
Afterpay
Love tools? Start earning points to redeem rewards on your next purchase Log in or Sign Up to redeem today!
Product Review Winner
Top 100 Relailer
30 Day Online Returns' with 'Australia's largest professional tool retailer

The FC Wireless v3003 AC-DC Voltage Measurement Kit is part of the Fluke Connect team of wireless test tools

Connect the v3000 FC Wireless AC Voltage and v3001 FC Wireless DC Voltage Modules to your test points, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

You'll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect® modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless Voltage Modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

Now you can take readings on moving machinery, with only the measurement module in harm's way.

Detailed Specifications
AC Voltage
Range 1 Resolution Accuracy 2 3 4 Accuracy 2 3 4
45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0% + 3 2.0% + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09% + 2
V 6.000 V 0.001 V 0.09% + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15% + 2
Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω 600.0 Ω 0.1 Ω 0.5% + 2
6.000 kΩ 0.001 kΩ 0.5% + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5% + 3
Diode test 2.000 V 0.001 V 1% + 2
µF 1000 nF 1 nF 1.2% + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF1 1 μF 10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function Range 1 Resolution Accuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5% + 3
400.0 mA 3 0.1 mA
mA DC 2 60.00 mA 0.01 mA 0.5% + 3
400.0 mA 3 0.1 mA
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range Resolution Accuracy 1
99.99 Hz 0.01 Hz 0.1% + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function Overload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale voltage Typical short circuit current
To 6 MΩ 50 MΩ
1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA
1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
mA Function
Overload Protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 x (specified accuracy) / °C (<18°C or >28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01) 3rd edition
CAN/CSA-C22.2 No 61010-1-12 3rd edition
UL 61010-1 3rd edition
IEC/EN 61010-1 2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution degree 2
Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight 340 g (12 oz)
Warranty Three years
Not compatible with Fluke CNX test tools

 

Fluke v3000 FC Wireless AC Voltage Module

Accuracy is specified as ±([% of reading] + [number of least significant digits]). All ranges are autoranging.
Accuracy is specified from 5% to 100% of the range obtained by autoranging, from 18°C to 28°C.

Specifications
Range ¹ / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
General Specifications
LCD w/ backlight 3½ digits, 6000 counts, updates 4/sec
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 Hours
Memory Record up to 65000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C
Altitude Operating 2,000 m
Storage 12,000 m
EMC EN 61326-1:2006
Safety compliance ANSI/ISA 61010-1 / (82.02.01) 3rd edition
CAN/CSA-C22.2 No 61010-1-12 3rd edition
UL 61010-1 3rd edition
IEC/EN 61010-1 2010
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree 2
Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight .22 kg (8 oz)
Warranty Three years
Not compatible with Fluke CNX test tools

 

Fluke v3001 FC Wireless DC Voltage Module

Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [Number of least significant digits]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18°C to 28°C.

Voltage Specifications
Function
mVDC Range ¹ / Resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 3
VDC Range ¹ / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 0.09% + 3
Range ¹ / Resolution 1000 V / 1 V
Accuracy 0.15% + 2
General Specifications
LCD w/ backlight 3 ½ digits, 6000 counts, 4/sec update rate
Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6
Log rate/interval Adjustable by PC from 1 sec to 1 hr, default 1 min
Battery life 400 hours minimum
Memory Record up to 65,000 readings
RF communications 2.4 GHz ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity 0% to 90% (0°C to 35°C), 0% to 75% (35°C to 40°C),
0% to 45% (40°C to 50°C)
EMC IEC 61236-1, Portable
Safety compliance IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Size (H x W x D) 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
Weight 0.255 kg (9 oz)
Warranty Three years
Not compatible with Fluke CNX test tools
Specification
Part No FLUFLKV3003FCKIT
Barcode 0095969724586
Brand Fluke
Warranty 1 Year

Reviews

Write Your Own Review