Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit is part of the Fluke Connect® team of wireless test tools

Connect the a3001 FC Wireless AC Current Module and flexible current probe to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

Now you can take readings on moving machinery, with only the measurement module in harm’s way.

The Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit provides measurement of many common electrical parameters

The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3001 FC Wireless iFlex® AC Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:

  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function

Specifications:

Fluke 3000 FC Series Wireless Multimeter

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [ Number of least significant digits ]).

AC Voltage
Range¹ / resolution   600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. Do not exceed 107 V-Hz.

 

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mV Range / resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 2
V Range / resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 0.09% + 2
0.15% + 2
))) Range / resolution 600 Ω / 1 Ω
Accuracy Meter beeps at
Ω Range / resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / resolution 2.000 V / 0.001 V
Accuracy 1% + 2
µF Range / resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy 1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.

 

AC and DC Current
mA AC
(45 Hz to 1 kHz)
Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
Accuracy 1.5% + 3
mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
Accuracy 0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.

 

Frequency
Range / resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy1 0.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

 

Input Characteristics
Overload protection 1100 Vrms
Input impedance (nominal) > 10 MΩ
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 Vrms
Input impedance (nominal) > 10 MΩ
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 Vrms
Input impedance (nominal) > 10 MΩ
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz

 

Open Circuit Test Voltage
Overload protection 1100 Vrms
Input impedance (nominal)  
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
 
Typical short circuit current  
Overload protection 1100 Vrms
Input impedance (nominal)  
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 VDC
Typical short circuit current

 

mA Function
Overload protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum

 

MIN/MAX Recording Accuracy
DC functions ±12 counts for changes > 350 mS in duration.
AC functions ±40 counts for changes > 900 mS in duration.

 

General Specifications
Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 x (specified accuracy) / °C ( 28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2


Fluke a3001 FC Wireless iFlex® AC Current Module

Specifications
Range 0.5 A to 2500 A AC
Resolution 0.1 A
Accuracy 3% ±5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
LCD w/ backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1 x (specified accuracy) / °C ( 28°C)
Operating humidity 90% at 35°C
75% at 40°C
45% at 50°C
Altitude Operating 2,000 m
Storage 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree 2
Jaw opening 25.4 cm (10 in) coil

Specifications

Specification
Part No FLUFLKA3001FCKIT
Barcode 95969724234
Brand Fluke
Warranty 3 Year

Pickup In Store

If you don't want to pay for delivery or need to ASAP, you can pick it up in store. Just bear in mind not all stores will have everything in stock. You'll be able to see if they do during the checkout process.

Free Delivery

Most products are included in free delivery, however some are excluded as follows:

  • Orders and/or items under $99.
  • Orders and/or items that are deemed bulky, large or heavy.
  • Clearance items.
  • Orders that include or items that are classed as dangerous goods.
  • Remote areas are excluded from free delivery and you will either be charged delivery at checkout or may be contacted prior to delivery to confirm delivery charges if necessary.
  • Interstate deliveries.

Total Tools reserve the right to change or withdraw free delivery at any time.

Estimated Delivery Timeframes

If you opted to collect in store you will receive an email to inform you when your goods are ready for collection.

If you opted for delivery, you will receive an email when the goods have been despatched to the couriers with details so you can track our order.

We aim to despatch all orders within 1-2 business days. In the unusual event of a delay to the despatch of your order you will be contacted at the earliest opportunity. Once the order has been despatched the estimated delivery time is as follows:

  • Metro (Excludes Hobart Metro) 1-2 business days
  • Hobart Metro 3-4 business days
  • Regional Areas 3-4 business days
  • Remote Areas 6-9 business days

Please note that these delivery timeframes are estimates and are not guaranteed.

Returns

Changed your mind? No worries. You just need to get the product back to the store it was shipped from (this is on your receipt) within 30 days, unused and in its original packaging and we'll give you a refund (excluding delivery costs). You can read our full returns & exchanges policy here (special order items are excluded from this returns policy).

Reviews

Write Your Own Review